Product Identification

Product ID:BATTERY,DRY,P/N M15072/12001
MSDS Date:04/09/1992
FSC:6140
NIIN:00-195-5341
MSDS Number: BPYDW

Responsible Party
CONCORDE BATTERY CORP
2009 SAN BERNARDINO RD
WEST COVINA, CA 91790-1006
US

Emergency Phone: 818-813-1234; NIGHTS 8OO-255-3924

Info Phone: 213-962-4006

Cage: 63017

Contractor
CONCORDE BATTERY CORP
WEST COVINA, CA 91790-1006 US

Telephone: 800-255-3924/818-813-1234

Cage: 63017

Ingredients

LEAD OXIDE (SARA III)

CAS: 1314-41-6

Fraction By Weight: 60%


LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 38%

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

LD50 LC50 Mixture:ORAL RAT LD50 IS NOT KNOWN
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:PRODUCT ITSELF IS NONTOXIC. HOWEVER,
PRODUCT CONTAINS LEAD WHICH IS TOXIC. SOME LEAD COMPOUNDS ARE
LISTED AS CARCINOGENIC. CONTACT WITH THE LEAD IS HIGHLY UNLIKELY
AND ONLY BECOMES A FACTOR IN CASE OF FIRE OR PHYSICAL DAMAGE TO
BATTERY. SULFURIC ACID MUST BE ADDED BEFORE USE. SEE SULFURIC ACID
MSDS FOR ACID HAZARDS.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE

First Aid

First Aid:FIRST AID IS GIVEN FOR LEAD DUST GENERATED WHEN HANDLING
DAMAGED BATTERIES. EYES: FLUSH WITH LARGE AMOUNTS OF WATER. IF
IRRITATION PERSISTS GET MEDICAL ATTENTION. SKIN: REMOVE
CONTAMINATED CLOTHING. W ASH AREA WITH SOAP AND WATER. IF SYMPTOMS
DEVELOP, GET MEDICAL ATTENTION. INHALATION: MOVE TO FRESH AIR.
INGESTION: DO NOT INDUCE VOMITING. GET MEDICAL ATTENTION.

Fire Fighting

Flash Point:NONFLAMMABLE
Extinguishing Media:THE PRODUCT ITSELF IS NONFLAMMABLE. USE MEDIA
APPROPRIATE FOR SURROUNDING FIRE, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:DO NOT USE WATER ON FIRES WHERE MOLTEN METAL
IS PRESENT. FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA TO PREVENT
THE POTENTIAL OF INHALING TOXIC FUMES.
Unusual Fire/Explosion Hazard:MOLTEN METALS PRODUCE FUMES AND/OR VAPORS
THAT MAY BE TOXIC OR RESPIRATORY IRRITANTS. THE PRODUCT CAN REACT
VIGOROUSLY WITH STRONG OXIDIZING AGENTS.

Accidental Release

Spill Release Procedures:THIS PRODUCT IS A DRY BATTERY AND IS
CONSIDERED AS NONSPILLABLE, IT IS PACKAGED ACCORDING TO 49CFR
PARAGRAPH 178.205 SPECIFICATION 12B. IN CASE OF AN ACCIDENT AND
CONTAINER IS BROKEN, PROTECTIVE GLOVE S WILL BE REQUIRED TO HANDLE
THE BATTERY PARTS.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:STORE IN COOL, DRY AREA. PROTECT FROM
PHYSICAL DAMAGE.
Other Precautions:NONE

Exposure Controls

Respiratory Protection:NONE REQUIRED UNDER NORMAL HANDLING.
Ventilation:NOT NORMALLY REQUIRED.
Protective Gloves:PROTECTIVE GLOVES FOR HANDLING PARTS.
Eye Protection:SAFETY GOGGLES FOR HANDLING PARTS.
Other Protective Equipment:NORMAL WORK CLOTHING.
Work Hygienic Practices:WASH AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
THIS NSN AND MSDS COVERS A DRY, LEAD/ACID BATTERY. SULFURIC ACID MUST
BE ADDED BEFORE USE OF THIS BATTERY. WHEN BATTERY IS BEING
ACTIVATED, SULFURIC ACID ADDED, SEE MSDS FOR SULFURIC ACID FOR
INFORMAT ION COVERING HAZARDS INVOLVED WHEN HANDLING SULFURIC ACID.

Chemical Properties

HCC:N1
Appearance and Odor:PLASTIC CASED DRY BATTERY. NO ODOR.
Percent Volatiles by Volume:NONE

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREMELY HIGH TEMPERATURE AND PHYSICAL
DAMAGE.
Hazardous Decomposition Products:MOLTEN METALS PRODUCE FUMES AND/OR
VAPORS THAT MAY BE TOXIC OR RESPIRATORY IRRITANTS.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSE OF WASTE BATTERIES IN ACCORDANCE WITH
LOCAL, STATE AND FEDERAL REGULATIONS FOR LEAD-ACID BATTERIES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.